![](banner/Prctech-th-1.jpg)
Product Category
11
>>
>>
Infusion Pump - เครื่องให้สารละลายทางหลอดเลือดดํา
>>
4
AKAS INFUMAX 5005
- Product Type: Volumetric Infusion Pump
- Power Supply: AC 100V to 280V 50Hz
- Battery Backup: 5-6 hrs @ drop/min or 2-3 hrs @ higher delivery rate
- Power Consumption: 10VA (W)
- Pumping mechanism: Linear Peristaltic
- Drop Sensors: External
- Air In Line Detector: Internal
- Display: LCD and 7 Segment LED Display
- Safety features: Excess / Less Alarm | Air in Line Protection | Sensor Malfunction Protection
- IV set ml conversion: Adult IV Sets - 20 to 176 drops/ml in steps of 0.5, Micro IV Sets - 30 to 85 drops/ml in steps of 1
- IV set tubing: Accepts all Brands of IV set, 100 brands user editable
- Drop rate range: 1 to 150 drops/min for Adult, 1 to 100 drops/min for Micro
- Volume rate range: 0.1 to 1200 mL/hr for Adult, 0.1 to 300 mL/hr for Micro
- Drop resolution: 1 drop/min
- Flow rate Resolution: 0.1 to 99.9 mL/hr in steps of 0.1 mL/hr, over 100 mL/hr and above in steps of 1 mL/hr
- Bolus Function: Auto Bolus, Purge Bolus
- Bolus Flow rate: Over 100 to 1200 mL/hr - Adult, 10 to 300 mL/hr - Micro
- Event Log: 5000 History stored
- Free Flow Protection: Free flow lower lock for protecting accidental excess flow
- Drug Library Mode: Drug library run mode with 16 default drugs and up to 100 drugs names can be user programmable
- Last Data ON/OFF: Last infusion rate and other parameters can be stored even after AC power is OFF
- Stand By: Pause Infusion facility from 1 min to 24 hours adjustable
- Occlusion Alarm: 3 level occlusion alarm
- Infused Volume: 0.1 to 9999.9 ml
- Target Volume: 0.1 to 10000 ml
- Bolus Volume: 0.1 to 500mL, 0.1 to 1000 mL (Adjustable)
- Elapsed Time: 00:01 to 99:59 hr
- Keep Vein Open (KVO): 0.1 to 99.9 mL/hr steps of 0.1mL/hr
- Battery charging period: 10 hrs automatic
- Battery type: Ni-MH 14.4V (4800 mAh) Rechargeable
- Audio and visual alarm: Target volume alarm & pre alarm, Excess flow, Less flow/ bolus Drip, Air in line, Battery low, Battery critical, KVO, Door Open or Tube Misleading, AC mains unplugged, AC mains plugged and Occlusion alarm, Pressure Drop & Internal malfunction
- Purge Flow: Flushing of the tube possible
- Menu Driven: Self Guided / Help Assisted Interactive Functions, Self Diagnosis of Alarm Causes (PC + ABS Plastic)
- Housing: PC + ABS Plastic
- Dimension: 148mm x 100mm x190mm (L x W x H)
- Weight: 2.0 kg
- Certification: CE:1023, ISO 13485:2016
- Connectivity (Optional): Wi-Fi
- Volume and time based flow rate calculation: Available
- Accuracy: ±5%, ±3% for all calibrated IV sets
- Operating & Storage-Temp: -10 to 40 degree C
- Operating & Storage-Humidity: 15 to 90% & 5 to 106 kpa
- IP protection: IPX4
- Classification: BF type, class II protection rating, in compliance with IEC / EN 60601, Class II in compliance with Council Directive 93/42/EEC
- Safety Testing: EN 60601-1, EN 60601-1-2, EN 60601-1-6, EN 60601-1-8, EN 60601-2-24